TECHNICAL SPECIFICATIONS FOR MODULAR SYSTEM TYPE OF CONTAINERS (LAMBRI)

TECHNICAL
DATAS
Snow Load     80 kg/m² TS 498 ve TS7046
Wind Speed                 102 km/saat (50 Kg/ m² ) TS 498
External Wall Heat Transmission Coefficient  K: 0,61 Kcal/m²hC ( K:0,71 W/m² K )
Internal Wall Heat Transmission Coefficient K: 0,58 Kcal/m²hC ( K:0,67 W/m² K )
Roof Heat Transmission Coefficient K: 0,39 Kcal/m²hC ( K:0,46 W/m² K )
Floor Heat Transmission Coefficient K: 3,45 Kcal/m²hC ( K:4,01 W/m² K )
Base-Plate(chassis) Load Capacity 200 kg/m² T.S 498.
Seismic zone Effective ground acceleration coefficient :Ao=0,40 (1degree seismic zone )
Building importance coefficient ( I =1)
Live load coefficient n:0,3
RELEVANT STANDARDS   DESIGN-STATIC : EUROCODE 3, TS 498, TS 7046, TS 648, TS
11372, Regulations about buildings which are to be erected in seismic
zone(06.03.2006).
Insulation: TS 825 , Heat insulation regulation (8.05.2000) 
 
Climate zone Wall insulation is suitable for 2. climatic zone ( K:0,60 W/m² K )
Roof insulation is suitable for ~ 2. climatic zone ( K:0,40 W/m² K )
Section of roof and walls can be thicker for other climatic
zone(optional)

TECHNICAL SPECIFICATIONS FOR MONOBLOK HEKIM SANDWICH PANEL CONTAINER

TECHNICAL DATAS Snow Load     80 kg/m²
Wind Speed                 102 km/saat
External Wall Heat Transmission Coefficient  K: 0,26 Kcal/m²hC
Internal Wall Heat Transmission Coefficient K: 0,26 Kcal/m²hC
Roof Heat Transmission Coefficient K: 0,68 Kcal/m²hC
Floor Heat Transmission Coefficient K: 3,85 Kcal/m²hC
Base-Plate(chassis) Load Capacity 200 kg/m² T.S 498. Calculated in accordance with T.S 498

 